PROBLEM

6.2Troubleshooting Fryers with Computer Magic III.5, Basket Lift Timer, or Digital Controller

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

 

A. Controller not turned on.

A. Press the ON/OFF switch to turn

 

the controller on.

 

 

 

 

B. Verify that the fryer is plugged in

 

B. No power to fryer.

and that the circuit breaker is not

 

 

tripped.

 

 

C. If available, substitute a harness

No display on

C. Damaged computer/controller

known to be good for the suspect

harness. If the fryer functions

computer or

wiring harness.

correctly, order replacement

controller.

 

 

harness from FASC.

 

 

 

 

D. If available, substitute a

 

 

computer/controller known to be

 

D. Failed computer/controller.

working for the suspect

 

computer/controller. If the fryer

 

 

 

 

functions correctly, order

 

 

replacement from FASC.

Display shows

 

If available, substitute a harness

Damaged computer/controller

known to be good for the suspect

with alarm

harness. If the fryer functions

wiring harness or connector.

sounding.

correctly, order replacement

 

 

 

harness from FASC.

 

A. Drain valve not fully closed.

A. Press the ON/OFF switch off,

 

 

close the drain valve(s)

 

 

completely, then press the

 

 

ON/OFF switch on.

 

B. Gas valve is not turned on.

B. Turn the gas valve knob to the

 

ON position.

Display shows

 

 

C. Verify that any in-line manual

with alarm

C. Manual gas shut off valve closed.

shut off valve is open. Verify that

sounding. Heating

 

gas main cut off valve is open.

indicator is on, but

D. Improperly connected quick-

D. Verify that the quick-disconnect

burners will not

fitting on the flexible gas line is

light.

disconnect fitting on gas line.

firmly connected to the fryer.

 

 

 

E. Verify that combustion air blower

 

 

is running. If not, call FASC for

 

E. Obstructed or failed combustion

service. If combustion air blower

 

air blower.

is functional, clean and adjust per

 

 

instructions in Chapter 5 of this

 

 

manual.