Frymaster Electric Fryer operation manual Portable Filter Pump Fails to Pump Oil?

Models: Electric Fryer

1 25
Download 25 pages 52.14 Kb
Page 21
Image 21
9.5.1 Portable Filter Pump Fails to Pump Oil?

9.5.1 Portable Filter Pump Fails to Pump Oil?

Filter Pump fails

to pump oil.

Does

your filter have a No heater?

Yes

Turn heater "ON" and run heater for 15 minutes.

Insert flexible oil return hose into the filter pan

holster. Turn pump motor "ON".

Does oil

No

flow?

 

Yes

 

Disconnect flexible oil return hose. Make sure it is cool before handling. Try blowing air through it.

Submerge hose into hot water over 49°C (120°F). Keep both ends out

No

Can you

of the water. If water gets into the hose, the water will cause severe

splattering when hose is reconnected to the filter.

Once shortening has softened, reconnect the flexible oil return hose to the filter.

Insert flexible oil return hose into the filter pan holster. Turn pump motor "ON".

Conduct normal

Yes

Does oil

No

filter operations.

 

flow?

 

blow air through

it?

Yes

Blockage is between the bottom of the filter pan and the flex hose valve. Go to page 22.

20

Page 21
Image 21
Frymaster Electric Fryer operation manual Portable Filter Pump Fails to Pump Oil?