9.5.3 Blockage between Filter Pan and Flex Hose Valve?
Heater Troubleshooting
Check wall circuit
breaker.
Blockage has been
determined to be between the filter pan bottom and the flex hose valve.
Does your
filter have aNo heater?
Yes
Verify power cord is connected to the outlet.
Turn the
No heater "ON". Does the suction line feel
warm?
Yes
If wall circuit breaker has |
| The heater is working | |
tripped, turn heater "OFF". |
| properly. | |
|
|
|
|
|
|
|
|
Reset wall circuit breaker.
Turn the heater "OFF".
Disconnect oil line from the filter pan to the pump at the pump end.
Put finger over the inlet connection to the pump.
Pump Troubleshooting
Turn heater "ON".
If the suction line fails to warm, the heater is faulty.
Check filter circuit breaker.
Push the circuit breaker
reset button.
Turn the pump "ON".
| No | Does the pump |
|
| motor run? |
Yes
Contact your local Factory Authorized Service Center!
Pump motor is clogged or
faulty.
Contact your local Factory Authorized Service Center.
No | Do you feel |
| suction? |
Yes
Pump is clear of any blockages. Go to Page 23 and continue.
22