Vent Tube

3.Pass a piece of ordinary binding wire (.052 inch diameter) through the tube to remove any obstruction.

4.Remove the wire, then blow through the tube to ensure it is clear.

5.Reinstall tube and bend so that the opening is pointing downward.

Check Burner Manifold Pressure

WARNING

Frymaster recommends that this task be performed by the local gas company or an

authorized service technician only.

1.Ensure that the gas valve knob is in the OFF position.

2.Remove the pressure tap plug from the gas valve assembly and attach the fitting for a gas pressure-measuring device to the tap.

Pressure

Tap Plug

Regulator Cap

3.Place the gas valve in the ON position. When the burner lights and continues below.

Place the controller power switch in the ON position. to burn, compare the indicated pressure to the table

4-3