6.8.3 Troubleshooting the 24 VAC Circuit in FBRA18 Units (Continued)

C

NOTE: All voltage measurements must be made within 4 seconds of unit calling for heat. If unit does not fire within 4 seconds, ignition modules will lock out and controller must be turned off then back on to reset.

Is 24VAC

present on J1 pin 5 Yes when unit calls for

heat?

No

Is 24VAC

present on N/O Yes terminal of 12VDC

relay?

No

Probable cause is failed wiring between latch relay and 12VDC relay.

Is J1 pin 2

Yes

grounded?

 

No

 

Clean lower water level sensor and ground it.

Does

CYCLE LED light No when unit calls for

heat?

Yes

Go to

"B".

Is 24VAC

present on COM

terminal of 12VDC relay Yes when unit calls for

heat?

No

Is

12VDC present

across coil of 12VDC relay Yes when unit calls for

heat?

No

Probable cause is

failed controller wiring

harness or failed

controller.

Probable cause is failed interface board.

Probable cause is failed wiring between relay and interface board.

Probable cause is failed 12VDC relay.

6-19

Page 46
Image 46
Frymaster FBRA18 Series manual Is J1 pin