5.2Troubleshooting Guides

NOTE: This guide applies

to FBRA18 units only.

Controller is not functioning.

Probable causes are failed 12V

transformer, failed interface board, or failed controller.

Probable causes are a failed

interface board or

failed/loose high-level water

sensor wiring.

Problem resolved.

Call FASC.

COOKPOT DID NOT FILL

WHEN UNIT WAS TURNED ON.

WATER SUPPLY TO UNIT

VERIFIED TO BE ON.

Did anything appear

No in controller display when unit was turned on?

Yes

Open control panel by

removing screws in each upper corner.

Is WATER

LED on interface board Yes illuminated?

No

Use bottlebrush to clean water level sensors.

No

Did LED

 

 

illuminate?

 

 

Yes

 

Yes

Did unit begin

No

 

to fill?

 

Probable causes are a failed

water solenoid or a failed

interface board.

5-2

Page 23
Image 23
Frymaster FBRA18 Series manual Troubleshooting Guides, To FBRA18 units only