Burner Manifold Gas

Pressures

Gas

Pressure

Natural

3.5" W.C.

0.8 kPa

 

LP

8.25" W.C.

2.5 kPa

 

4.If necessary, adjust the burner gas pressure by removing the cap from the gas valve regulator and turning the regulator screw to obtain the correct pressure. When the correct pressure is obtained, reinstall the cap.

5.Place the controller power switch and the gas valve in the OFF position. Remove the fitting from the pressure tap hole and reinstall the pressure tap plug.