BURNERS DO

NOT LIGHT.

Verify that correct setpoint has been programmed, that main gas supply valve is open, and that equipment gas valve is set to ON. Press ON/OFF button.

Did burners

Yes

Problem

light?

 

resolved.

No

 

 

Use bottlebrush to clean low water sensor. If burners still do not light, remove the cover over the water sensors and thoroughly clean them with a Scotchbrite or similar nylon pad.

Did burners

Yes

Problem

light?

 

resolved.

No

 

 

Open control panel by removing screws in each upper corner.

Is HEAT LED

Yes

Problem is with the gas

on interface board

supply or ignition system.

 

illuminated?

 

Call FASC.

No

 

 

Problem is with a

failed interface board or a malfunctioning computer.

Call FASC.

5-5

Page 26
Image 26
Frymaster FBRA18 Series manual Yes