Frymaster MJCFEC, FMCFEC, J3F Checking Burner Manifold Gas Pressure cont, Adjusting Pilot Flame

Models: JCFX J65X J3F KJ3FC MJCF MJCFE FMCFE FMCFEC MJCFEC

1 88
Download 88 pages 29.49 Kb
Page 11
Image 11
1.3 Checking Burner Manifold Gas Pressure (cont.)

MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1.3 Checking Burner Manifold Gas Pressure (cont.)

Non-CE Standard

for Incoming Gas Pressures

Gas

Minimum

Maximum

 

6" W.C.

14" W.C.

Natural

1.49 kPa

3.48 kPa

 

14.93 mbar

34.84 mbar

 

11" W.C.

14" W.C.

LP

2.74 kPa

3.48 kPa

 

27.37 mbar

34.84 mbar

Non-CE Standard

for Burner Manifold Gas Pressures

Gas

Pressure

Natural

3.5" W.C.

.75 kPa

 

7.5 mbar

LP

8.25" W.C.

2.0 kPa

 

20.0 mbar

4.If the measured manifold gas pressure does not match the appropriate pressure in the preceding tables, remove the cap from the gas valve regulator and adjust to the correct pressure.

Honeywell Valve

Honeywell Valve

(Non-CE Units)

(CE Units)

Regulator Adjustment Screw Cap

1.4 Adjusting Pilot Flame

1.On non-CE valves, remove the cap covering the pilot adjustment screw. On all valves, turn the pilot adjustment screw counterclockwise to increase the length of the flame or clockwise to decrease the length of the flame. Adjust the flame to a length of 1 to 1-½ inches (25 to 38 mm).

On Non-CE gas valves, remove this cap to

Pilot Adjustment Screw

access Pilot Adjustment Screw.

 

Honeywell Valve

Honeywell Valve

(Non-CE Units)

(CE Units)

2.On Non-CE valves, reinstall the pilot adjustment screw cap.

1-6

Page 11
Image 11
Frymaster MJCFEC, FMCFEC, KJ3FC Checking Burner Manifold Gas Pressure cont, Adjusting Pilot Flame, Service Procedures