CHAPTER 1: SERVICE PROCEDURES

Pilot

Generator

High-Limit

Operating

Thermostat

Thermostat

Optional ON-OFF switch

 

 

 

 

 

High-limit

 

 

 

 

 

Thermostat

 

 

 

 

 

12C

 

 

. A d j

 

 

Safety Drain

 

 

P iol t

 

 

Switch

 

 

 

 

 

Pilot

 

PS1/2I

 

 

 

 

HONEYW E LL

 

1/2 P.S.I.

17C

 

 

 

Generator

 

 

 

 

P ILO T

C

 

 

 

 

HONEYWELL

 

 

 

 

 

In Line Splice

HONEYWELL

ON

 

OFF

 

1/2 PSI

 

 

 

 

 

 

 

 

 

 

ON/OFF Switch

 

 

 

 

 

(Optional)

 

 

 

 

 

17C

 

 

 

 

 

In Line Splice

 

 

 

 

 

FENWALL

 

 

 

 

 

Operating

 

 

 

 

 

Thermostat

When troubleshooting millivolt systems, always check these areas before performing diagnostic checks on either the Robertshaw or Honeywell systems:

A.Inspect all wires and component leads for damage (heat, oil, moisture, etc.). On capillary tube-type thermostats, check for resistance on the thermostat lead wires. Wire nuts and other connectors cannot be present in a millivolt circuit as they can cause resistance. If resistance is found, solder the connectors to the wires or replace the wires.

B.Clean and verify that all wire connections and gas valve terminal connections are tight.

C.Check the length of the pilot flame (it should be about 1½-inches (38mm) long) and verify that it contacts the top one third of the thermopile. Clean the pilot orifice and adjust the pilot strength if needed.

D.Measure thermopile output with no load (i.e., with the thermopile disconnected from the gas valve). Measurements must be made with a multimeter having a 0-1000 DC millivolt (MV) range. Light the pilot and have someone hold the gas cock knob in the depressed position. If the thermopile is a single lead (coaxial) type, measure from the lead’s end contact to its screw-in threads. If the thermopile has two leads, measure across the end terminals. The reading should be within the range of 500-800 millivolts. If not, replace the thermopile.

Performing diagnostic checks on Robertshaw and Honeywell Systems are described on the following page.