Frymaster MJCFEC, FMCFEC, J3F SERVICE PROCEDURES 1.8.9 Replacing Burner Ceramic Targets, Danger

Models: JCFX J65X J3F KJ3FC MJCF MJCFE FMCFE FMCFEC MJCFEC

1 88
Download 88 pages 29.49 Kb
Page 20
Image 20
CHAPTER 1: SERVICE PROCEDURES

MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1.8.9 Replacing Burner Ceramic Targets

1.Disconnect fryer from electrical and gas supplies. DANGER

Drain the frypot or remove the handle from the drain valve before proceeding further.

1.Disconnect fryer from electrical and gas supplies.

2.On FMCF fryers, remove square-drain sections as necessary to expose burner.

3.Disconnect the wires from the gas valve terminal block, marking each wire to facilitate connections.

4.Remove the high-limit thermostat wires from the gas valve pilot coil.

5.Disconnect the pipe union collar at the left side of the gas valve (arrow).

Disconnect union (arrow) to remove burner manifold assembly.

6.Remove front burner shields to access burner assembly.

7.Remove the burner heat shield hanger screws at the front of the burner and remove the heat shield.

8.Remove the burner hanger screws and lower the front of the main burner. Pull it forward to clear the rear burner hanger, and then lower the burner to the floor.

9.Raise the front of the fryer enough to slide the burner from under the fryer cabinet.