Frymaster MJCFEC, FMCFEC, KJ3FC, J65X, JCFX manual SERVICE PROCEDURES 1.8.12 Replacing Frypot cont

Models: JCFX J65X J3F KJ3FC MJCF MJCFE FMCFE FMCFEC MJCFEC

1 88
Download 88 pages 29.49 Kb
Page 24
Image 24
CHAPTER 1: SERVICE PROCEDURES

MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1.8.12 Replacing Frypot (cont.)

13.Remove the cover from the safety drain switch, disconnect the wires from the switch, and pull them out of the switch box.

14.Pull up and forward on the component shield to clear the rear mounting stud on the front of the frypot and remove it from the fryer by rotating its right side up and to the left.

15.Disconnect the pipe union on the right side of the gas valve.

16.On FMCF fryers, remove the section of square drain from the drain valve of the frypot to be removed.

17.Remove the frypot hold-down bracket.

18.Remove the screws from the flue cap sides and back, and lift it clear of the fryer(s).

19.Remove the oil return line from the front of the frypot to be removed.

20.Lift the complete frypot assembly (frypot, burner, gas valve, and flue) from the fryer cabinet.

21.Transfer the burner heat shield and burner to the replacement frypot.

22.Remove the drain valve, thermostat or temperature probe, and high-limit thermostat and install on replacement frypot.

15.Disconnect the pipe union on the right side of the gas valve. CAUTION

Before installing the thermostat/temperature probe, high-limit thermostat, and drain valve on the replacement frypot, clean their threads and apply Loctite PST567 thread sealant or equivalent to the threads.

23. Reverse steps 1-22 to reassemble the fryer.

1-19

Page 24
Image 24
Frymaster J3F, MJCFEC, FMCFEC SERVICE PROCEDURES 1.8.12 Replacing Frypot cont, Master Jet Cf Series Atmospheric Gas Fryers