Frymaster OCF30 operation manual Danger

Models: OCF30

1 46
Download 46 pages 29.51 Kb
Page 20
Image 20
Manual background

Manual background DANGER

NEVER attempt to clear a clogged drain valve from the front of the valve! Hot oil will rush out creating the potential for severe burns.

Manual background DANGER

DO NOT hammer on the drain valve with the cleanout rod or other objects. Damage to the ball inside will result in leaks and will void the Frymaster warranty.

4.After the oil has drained from the frypot and when prompted, rotate the filter handle towards the I” to start the pump and begin the filtering process. There may be a slight delay before the pump activates (see Figure 8).

Rotate filter handle to the “I” to start the pump. (Position of handle may differ from

Figure 8

5.The filter pump draws the oil through the filter medium and circulates it back up to and through the frypot during a filter.

6.After the oil is filtered, close the drain valve when prompted and allow the fryer to refill. Let the filter pump run 10 to 12 seconds after the oil begins to bubble. Turn the filter off.

7.Ensure the drain valve is fully closed. (If the drain valve is not fully closed, the fryer will not operate.)

8.Turn the filter off when prompted.

The computer displays OFF when finished.

Manual background WARNING

The filter pump is equipped with a manual reset switch in case the filter motor overheats or an electrical fault occurs. If this switch trips, turn off power to the filter system and allow the pump motor to cool 20 minutes before attempting to reset the switch (see photo below).

Filter Pump Reset Switch

4-4

Page 20
Image 20
Frymaster OCF30 operation manual Danger