Problem | Probable Causes | Corrective Action | ||||
| Frypot temperature has dropped more | This display is normal for a short while if | ||||
Controller displays lo | than 21ºF (12ºC) for CM3.5 or 30°F | a large batch of frozen product is added to | ||||
or LOw temp. | (17°C) for 3000 controllers below | the frypot | or | if the fryer is not heating | ||
setpoint in idle mode or 45°F (25°C) in | properly. | If | the issue persists call your | |||
| ||||||
| cook mode. | FAS for assistance. | ||||
Controller displays | Frypot temperature is more than 410ºF | Shut the fryer down immediately and call | ||||
(210ºC) or, in CE countries, 395ºF | your FAS for assistance. | |||||
hot or | ||||||
(202ºC). |
|
|
|
| ||
| Press the power button to turn off fryer | |||||
Controller displays Hi | Frypot temperature is more than 40 ºF | |||||
and let cool before returning power to | ||||||
temp. | (4ºC). | fryer. If issue continues call your FAS for | ||||
|
| assistance. |
|
|
| |
|
| This display is normal if the fryer setpoint | ||||
|
| has been changed to a lower temperature. | ||||
| Fryer is more than 21ºF (12ºC) above | The display should revert to the normal | ||||
CM III.5 displays HI. | four dashes when the frypot temperature | |||||
setpoint. | cools to the setpoint. If the setpoint has | |||||
| ||||||
|
| not been changed, this indicates a problem | ||||
|
| with the temperature control circuitry. | ||||
|
| Turn the fryer off and call FAS. | ||||
Controller displays | A. Open drain valve | A. Close the drain valve. | ||||
B. Failed high limit | B. Shut the fryer down immediately and | |||||
hELP | ||||||
limit failure. |
| call your FAS for assistance. | ||||
|
|
|
|
| ||
|
| Shut the fryer down and call your FAS for | ||||
Controller displays | Problem with the temperature measuring | |||||
TEMP PROBE | circuitry including the probe or damaged | assistance. |
|
|
| |
FAILURE or PROB. | controller wiring harness or connector. |
|
|
|
| |
Heating indicator is on, |
| Verify that both the main power cord and | ||||
Three phase power cord unplugged or | 120V is fully seated in its receptacle, | |||||
but fryer is not heating. | locked into place and that circuit breaker is | |||||
circuit breaker is tripped. | ||||||
|
| not tripped If the problem continues call | ||||
|
| your FAS for assistance. | ||||
|
|
|
| |||
Controller displays |
| Clear error and silence the alarm by | ||||
| pressing the S (YES) button. Maximum | |||||
RECOVERY | Recovery time exceeded maximum time | |||||
recovery time for electric is 1:40. If this | ||||||
FAULT/ YES and | limit. | |||||
error continues call your FAS for | ||||||
alarm sounds. |
| |||||
| assistance. |
|
|
| ||
|
|
|
|
| ||
Controller displays |
| Press the S (YES) button if the issue is | ||||
| fixed or press the T (NO) button to | |||||
SERVICE | An error has occurred which requires a | |||||
continue cooking and call your FAS for | ||||||
REQUIRED followed | service technician. | |||||
assistance. In some cases, cooking may not | ||||||
by an error message. |
| |||||
| be available. |
|
| |||
|
|
|
| |||
6.2.3 Basket Lift Problems |
|
|
|
| ||
|
|
|
| |||
PROBLEM | PROBABLE CAUSES | CORRECTIVE ACTION | ||||
Basket lift movement is |
| Apply a light coating of Lubriplate™ or |
| |||
Basket lift rods need lubrication. | similar lightweight white grease to the |
| ||||
jerky and/or noisy. |
| |||||
| rod and bushings. |
| ||||
|
|
|