Frymaster OCF30 Press the check 9 button 4.Enter, The controller displays HIGH LIMIT YES/NO

Models: OCF30

1 46
Download 46 pages 29.51 Kb
Page 33
Image 33

2.Press the left arrow (W) button until TECH MODE is displayed.

3.Press the check (9) button.

4.Enter 3000.

5.Press the left arrow (W) button until HI LIMIT TEST is displayed.

6.Press the check (9) button.

The controller displays HIGH LIMIT YES/NO.

7.Press the up arrow (S) button.

8.The controller displays PRESS AND HOLD CHECK.

9.Press and hold the (9) button to initiate the high-limit test.

The vat begins to heat. The computer displays the actual vat temperature during the test.

The fryer continues heating until the high limit trips. Generally this happens once the temperature reaches 423°F to 447°F (217°C to 231°C) for non-CE high limits and 405°F to 426°F (207°C to 219°C) for CE high limits.

Once the high-limit opens the computer displays HELP HI-2alternating with the actual temperature (ex. 430F).

10. Release the (9) button.

If the high-limit fails, the computer displays HIGH LIMIT FAILURE alternating with DISCONNECT POWER. If this happens, disconnect power to the fryer and call for service immediately.

The vat stops heating and the computer displays the current temperature setting alternating with the actual temperature (ex. 430F) until the temperature cools below 400°F (204°C).

11.Press the soft power button to cancel the alarm and go to OFF.

12.Follow the procedure to dispose of the oil.

6-6

Page 33
Image 33
Frymaster OCF30 Press the check 9 button 4.Enter, The controller displays HIGH LIMIT YES/NO, Press the up arrow S button