Frymaster YSCF14G operation manual Electrical Connections, Gas Connections cont

Models: YSCF14G

1 26
Download 26 pages 40.27 Kb
Page 8
Image 8
3.If disconnection of the restraint is necessary, this restraint must be reconnected after the fryer has been returned to its originally installed position.

YSCF14G SERIES GAS FRYERS

CHAPTER 1: INSTALLATION

1.1Gas Connections (cont.)

3.If disconnection of the restraint is necessary, this restraint must be reconnected after the fryer has been returned to its originally installed position.

J.After hook-up, bleed the gas line of air to ensure that the pilot light will ignite quickly.

K.CE Standards: If the unit is to be installed with flexible coupling, use a commercial flexible coupling certified as NF D 36123 (or other national standard) or a quick disconnect device certified NF D 36124 (or other national standard).

1.2Electrical Connections

The fryer when installed must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70-(latest edition).

1.2Electrical Connections DANGER

This fryer is equipped with a three-prong (grounding) plug for protection against electrical shock and must be plugged directly into a properly grounded, three-prong receptacle. DO NOT CUT, REMOVE, OR OTHERWISE BYPASS THE GROUNDING PRONG ON THIS PLUG!

The rating plate and wiring diagram are located inside the front door. The fryer is equipped with a 120VAC single-phase 60-hertz system (Domestic), or 230VAC single-phase 50-hertz system (International/CE). Do not cut or remove the ground prong from the power cord plug. Do not attempt to use the fryer during a power outage.

Manual background DANGER

This appliance requires electrical power for operation. Place the gas control valve in the OFF position in case of a prolonged power outage. Do not attempt to operate this appliance during a power outage.

1-4

Page 8
Image 8
Frymaster YSCF14G operation manual Electrical Connections, Gas Connections cont