Frymaster YSCF14G operation manual 3-10

Models: YSCF14G

1 26
Download 26 pages 40.27 Kb
Page 20
Image 20
3-10

YSCF14G SERIES GAS FRYERS

CHAPTER 3: BUILT-IN FILTRATION

3.4.2 Filter Operation (cont.)

9.After all oil is pumped back into the frypot, bubbles form, indicating air in the oil return lines. Allow the oil to bubble for 10-15 seconds to ensure all oil is evacuated from the return lines. Twist the red handle to close the oil return valve and deactivate the filter pump.

Allow the oil to bubble for 10-15 seconds to ensure evacuation of all shortening/oil in the return lines.

10.If the oil level is low, add oil until the level is at the top OIL LEVEL line. Remember, the oil is at operating temperature.

Add oil until the oil level is at the top OIL LEVEL line. DO NOT OVERFILL THE FRYPOT.

11.Replace the frypot grid, using care not to splash hot oil. Turn the fryer on.

Replace the frypot grid, using care not to splash hot oil.