Frymaster operation manual Periodic/Annual, YSCF14G SERIES GAS FRYERS PREVENTATIVE MAINTENANCE

Models: YSCF14G

1 26
Download 26 pages 40.27 Kb
Page 24
Image 24
YSCF14G SERIES GAS FRYERS

YSCF14G SERIES GAS FRYERS

CHAPTER 5: PREVENTATIVE MAINTENANCE

5.4 Periodic/Annual

This appliance should be inspected and adjusted periodically by qualified service personnel as part of a regular kitchen maintenance program.

Frymaster recommends that this appliance be inspected at least annually by a Factory Authorized Service Technician as follows:

Inspect the cabinet inside and out, front and rear for excessive oil build-up and/or oil migration.

Verify that the flue opening is not obstructed by debris or accumulations of solidified oil or shortening.

Verify that burners and associated components (i.e. gas valves, pilot assemblies, ignitors, etc.) are in good condition and functioning properly. Inspect all gas connections for leaks and verify that all connections are properly tightened.

Verify that the burner manifold pressure is in accordance with that specified on the appliance’s rating plate.

Verify that the temperature and high-limit probes are properly connected, tightened and functioning properly, and that mounting hardware and probe guard are present and properly installed.

Verify that component box components (i.e. computer/controller, transformers, relays, interface boards, etc.) are in good condition and free from oil migration build-up and other debris. Inspect the component box wiring and verify that connections are tight and that wiring is in good condition.

Verify that all safety features (i.e. drain safety switches, reset switches, etc.) are present and functioning properly.

Verify that the frypot/cookpot is in good condition and free of leaks and that the frypot/cookpot insulation is in serviceable condition. Verify that the frypot tube diffusers are present and in good condition (i.e. no visible deterioration or damage).

Verify that wiring harnesses and connections are tight and in good condition.

Built-in Filtration:

Inspect all oil-return and drain lines for leaks and verify that all connections are tight.

Inspect the filter pan for leaks and cleanliness. Empty crumbs in the crumb basket into a fireproof container. Clean basket daily. Advice owner/operator not to allow crumbs to accumulate in basket. Insist they clean the basket daily.

Verify that all O-rings and seals (including those on quick-disconnect fittings) are present and in good condition. Replace O-rings and seals if worn or damaged.

5-2

Page 24
Image 24
Frymaster operation manual Periodic/Annual, YSCF14G SERIES GAS FRYERS PREVENTATIVE MAINTENANCE