Fujitsu AUU36RC, AUU18RC, AUU42RC, AOU18RC, AOU36RC, AOU24RC Troubleshooting, En-17, Symptom, Problem

Models: AOU42RC AOU24RC AOU18RC AUU42RC AUU24RC AOU36RC AUU18RC AUU36RC

1 19
Download 19 pages 25.11 Kb
Page 18
Image 18
TROUBLESHOOTING

TROUBLESHOOTING

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the elec-

WARNING! trical breaker, and consult authorized service personnel.

Merely turning off the unit’s power switch will not completely disconnect the unit from the power source. Always be sure to turn off the electrical breaker to ensure that power is completely off.

Before requesting service, perform the following checks:

 

Symptom

Problem

See Page

 

 

 

 

 

 

NORMAL

Doesn’t operate immedi-

● If the unit is stopped and then immediately started again, the com-

 

FUNCTION

ately:

pressor will not operate for about 3 minutes, in order to prevent

 

 

 

fuse blowouts.

 

 

 

 

 

 

 

● Whenever the electrical breaker is turned off then on again, the

 

 

 

protection circuit will operate for about 3 minutes, preventing unit

 

 

 

operation during that period.

 

 

 

 

 

 

 

 

Noise is heard:

● During operation and immediately after stopping the unit, the

 

 

 

sound of water flowing in the air conditioner’s piping may be

 

 

 

heard. Also, noise may be particularly noticeable for about 2 to 3

 

 

 

minutes after starting operation (sound of coolant flowing).

 

 

● During operation, a slight squeaking sound may be heard. This is

 

 

 

the result of minute expansion and contraction of the panel due

 

 

 

to temperature changes.

 

 

 

 

 

 

 

 

 

*● During Heating operation, a sizzling sound may be heard occa-

 

 

 

sional. This sound is produced by the Automatic Defrosting op-

15

 

 

eration.

 

 

 

 

 

 

 

 

Smells:

● Some smell may be emitted from the indoor unit. This smell is

 

 

 

the result of room smells (furniture, tobacco, etc.) which have

 

 

been taken into the air conditioner.

 

 

 

 

 

 

 

 

Mist or steam are

● During Cooling, a thin mist may be seen emitted from the indoor

 

 

emitted:

unit. This results from the sudden Cooling of room air by the air

 

 

emitted from the air conditioner, resulting in condensation and

 

 

 

misting.

 

 

 

 

 

 

 

 

 

*● During Heating operation, the outdoor unit’s fan may stop, and

 

 

 

steam may be seen rising from the unit. This is due to Automatic

15

 

 

Defrosting operation.

 

 

 

 

 

 

 

 

Air flow is weak or stops:

*● When Heating operation is started, fan speed is temporarily very

 

 

 

low, to allow internal parts to warm up.

 

 

 

*● During Heating operation, if the room temperature rises above

 

 

 

 

 

the thermostat setting, the outdoor unit will stop, and the indoor

 

 

 

unit will operate at very low fan speed. If you wish to warm the

 

 

 

room further, set the thermostat for a higher setting.

 

 

 

 

 

 

 

 

 

*● During Heating operation, the unit will temporarily stop opera-

 

 

 

tion (between 2 and 16 minutes) as the Automatic Defrosting mode

15

 

 

operates. During Automatic Defrosting operation,

DEFROST

will

 

 

 

 

 

be shown on the remote controller display.

 

 

 

 

 

 

 

 

 

● The fan may operate at very low speed when the unit is monitor-

4

 

 

ing the room’s temperature.

 

 

 

 

 

 

 

 

 

 

 

● In the monitor AUTO operation, the fan will operate at very low

4

 

 

speed.

 

 

 

 

 

 

 

 

 

 

Water is produced from

*● During Heating operation, water may be produced from the out-

15

 

the outdoor unit:

door unit due to Automatic Defrosting operation.

 

 

 

 

 

 

En-17

Page 18
Image 18
Fujitsu AUU36RC, AUU18RC, AUU42RC, AOU18RC, AOU36RC, AOU24RC, AOU42RC, AUU24RC Troubleshooting, En-17, Symptom, Problem