5.Select whether "Daylight Savings Time" should be on or off.
This option is not shown for timezones where daylight savings time is not used.
6.Press the [OK] button.
⇒The Region/Timezone is set. Continue with IP address/DHCP settings.
3.5 Setting the IP Address/DHCP
An IP address must be set in order to connect the scanner to a network.
Do not use an IP address that already
ATTENTION | exists in the network. |
| |
| IP address duplication will cause an |
| error during setup. |
1.Select the [Network Settings] tab on the top menu.
2.Select the [IP Address] tab on the left side menu.
⇒The IP address/DHCP screen appears.
3.Set the scanner's IP address. This may be done automatically, by pressing the DHCP [On] button.
The IP address may also be set manually, by pressing the DHCP [Off] button and entering the following numerical addresses:
•IP Address
•Subnet Mask
•Default gateway
4.Press the [OK] button.
⇒The information entered is set.
If the IP address is the same as one
HINT | already in use, network communication |
| |
| problems will occur. In this case, try the |
| following steps: |
1.Disconnect the LAN cable and turn the scanner off.
2.Reboot the scanner with the LAN cable still disconnected, and enter a non- duplicate IP address.
3.
When DHCP is set to "On", the following settings are assigned by the DHCP:
•IP Address
•Subnet Mask
•Default Gateway
•DNS Server
•WINS Server
Even if DNS or WINS server is set, priority is given to the scanner settings over the DHCP settings.
Continue with the DNS settings.
Network Scanner |