Appendix C Replacing Consumable Parts

 

 

 

 

 

The glass scanner windows

 

￿￿￿￿￿￿￿

inside the ADF can become hot

 

 

when the scanner is used.

 

 

Before cleaning inside the scanner or replacing any parts, turn off the power, unplug the AC adapter from the outlet, and wait

ATTENTION

Use only the PFU LIMITED parts specified. Do not use consumable parts made by other manufacturers.

for at least 15 minutes.

The following diagram shows the locations of the consumable parts in the scanner. For more details, refer to "5.5 Replacing Parts" in the "Network Scanner fi-6000NS Operator's Guide".

Replacement Part No. and
Pad Assembly (PAD ASSY)
Standard Replacement Cycles

The usage count of consumable parts can be checked in administrator mode on the "Usage Status" screen.

Pick Roller

Pick Roller

When parts need to be replaced soon, the "Status" information field becomes orange. When parts need to be replaced immediately, the "Status" information field becomes red.

The following table specifies the replacement part numbers and the standard replacement cycles.

Part name

Replacement cycle

 

 

 

 

Pad Assembly

After every 50,000 sheets scanned or

(PA03289-0111)

once a year

 

 

Pick Roller

After every 100,000 sheets scanned

(PA03289-0001)

or once a year

 

 

To obtain these parts, contact your FUJITSU dealer or an authorized FUJITSU scanner service provider. These replacement cycles are rough guidelines when

using 64 g/m2 (17 lb) A4/Letter woodfree or wood containing paper. They may vary according to the type of documents scanned, scanner usage, and cleaning frequency.

Pick Roller's Shaft

Network Scanner fi-6000NS Getting Started

 

15