7.70
7.70 FLD (Single Precision Floating Point Data Load)Loads the value at memory address Rj to FRi.
●Assembler Format
FLD @Rj, FRi
●Operation
(Rj) → FRi
●Classification
Single-precision floating point instruction, FR81 family
●Execution Cycles
a cycle
●Instruction Format
●EIT Occurrence and Detection
A data access protection violation exception, an invalid instruction exception (a data access error or FPU
absence error), or an interrupt is detected.
MSB LSB
(n+0)000001111100 Rj