CHAPTER 7 DETAILED EXECUTION INSTRUCTIONS
7.135
7.135 MULU (Multiply Unsigned Word Data)Multiplies the word data in Rj by the word data in Ri as unsigned numbers and stores
the resulting unsigned 64-bit data with the higher word in the multiplication/division
register (MDH), and the lower word in the multiplication/division register (MDL).
●Assembler Format
MULU Rj, Ri
●Operation
Ri × Rj → MDH, MDL
●Flag Change
N: Set when the MSB of the MDL of the operation result is "1", cleared when the MSB is "0".
Z: Set when the MDL of the operation result is zero, cleared otherwise.
V: Cleared when the operation result is in the range 0 to 4294967295, set otherwise.
C: Unchanged.
●Classification
Multiply/Divide Instruction
●Execution Cycles
5 cycles
●Instruction Format
NZVC
CCC-
MSB LSB
10101011 Rj Ri