C120-E360-06EN 4-1
CHAPTER 4 Error Status
1

4.1 setrci error status

When the RCI construction by the setrci command ends abnormally and "Operation

failed error status: XX" is displayed, the displayed error status code and explanation

are described to the following table.

Code Explanation
00 Detected the duplicate RCI address.
01 RCI address of current unit is not configured or false.
02 Detected the duplicate RCI address of RCI host, or detected the undefined RCI
address.
03 RCI address of current unit is not configured.
04 Over maximum entry of RCI table.
05 Detected anomaly in RCI table receiving.
06 Detected anomaly in RCI table sending.
07 Receiving status check from undefined RCI device.
08 Detected the loss of RCI master.
09 Detected anomaly of RCI table.
0a Synchronous time out of RCI table.
0b Synchronous retry out of RCI table.
0c Detected anomaly of RCI table.
0d Failed the version check of RCI table.
0e Detected anomaly of RCI table.
0f Detected anomaly in synchronous with RCI Neuron chip.
20 Detected the duplicate RCI address in RCI I/O unit (Expansion file unit,
External power controller).
30 Detected the duplicate RCI address in RCI I/O unit (Line selector switch).
fd RCI construction cannot be constructed, or it was cancelled.
fe Other RCI unit is constructing the RCI network.
ff RCI setup procedure is false.