2-6 C120-E360-06EN
CHAPTER 2 Setup of the RCI for Operation
2.4 RCI Setup for Addition of an RCI Base Cabinet

2.4.1 RCI setup flow

RCI setup for addition of an RCI host contains the following steps:
1Confirming RCI initialization
2Connecting an RCI cable
3Making an RCI address setting
4Making an RCI expansion setting

2.4.2 Confirming RCI initialization

Before connecting an RCI cable to an RCI host, confirm that RCI settings have been
initialized.
To confirm RCI initialization:
1Execute the setrci (8) command to display the RCI status.
Confirm that "address" is 000f7fff (initial address value).
If RCI settings have not been initialized, perform the next step.
2Execute the setrci (8) command to initialize RCI settings.

2.4.3 Connecting an RCI cable

Connect an RCI cable to the RCI host to be added.
1Insert a T-branch connector and an RCI cable into the existing set of connections
of RCI cables.
XSCF> setrci -c stat
HOST
address 000f7fff
Inactive
The command completed successfully.
XSCF> setrci -c init