1.3 Operator panel
The operator panel is located on the right side of the scanner. The panel consists of a Function Number Dis- play, four buttons and a LED.
|
| Function No. |
|
| display |
|
| Function |
|
| Send to |
|
| Scan |
|
| Power button |
|
| LED |
. |
|
|
| Name | Function |
Function Number | Indicates the state of the scan- | |
Display |
| ner. The meaning of the num- |
|
| bers and alphabets indicated |
|
| are explained later in this sec- |
|
| tion. |
Buttons | Function | Changes the Function activated |
|
| by the [Send to] button (*). |
| Send to | Launches the linked applica- |
| Scan | tion software (*). |
|
| |
| Power button | Turns the scanner ON and |
|
| OFF. |
LED | - | Lights when the scanner is |
|
| turned ON. |
*) About the settings on the launcher, refer to FUJITSU TWAIN32 scanner driver help and
■Indications on the Function Number Display
The following shows the indications on the Function Number Display.Indication | Meaning |
|
|
8 | Lights only one time upon turning on the |
scanner. | |
|
|
P | Indicates that the scanner has been turned |
ON and is being initialized. | |
0 | Indicates that initialization will soon be |
completed. | |
|
|
1 | Indicates that initialization has been com- |
pleted successfully. | |
| This status is called "Ready Status." |
|
|
U | Indicates that a temporary error (that users |
can solve) has occurred during the initial- | |
| ization or scanning of documents. |
| [U] and an error number (1, 2, 6) are dis- |
| played alternately. |
| To return the scanner to the ready status |
| ([1]), press the [Scan] or [Send to] button |
| while the error is indicated. |
E | Indicates that a device alarm (that users can |
not solve) has occurred during the initial- | |
| ization or scanning of documents. |
| [E] and an alarm number (2 to 9, and, c, d, |
| F) are indicated alternately. |
| To return the scanner to the ready status |
| ([1]), press the [Scan] or [Send to] button. |
| If this alarm occurs, turn the power off and |
| then on again. If the alarm is indicated after |
| turning on the power again, contact your |
| servic engineer. |
2