1.3 Operator panel

The operator panel is located on the right side of the scanner. The panel consists of a Function Number Dis- play, four buttons and a LED.

 

 

Function No.

 

 

display

 

 

Function

 

 

Send to

 

 

Scan

 

 

Power button

 

 

LED

.

 

 

 

Name

Function

Function Number

Indicates the state of the scan-

Display

 

ner. The meaning of the num-

 

 

bers and alphabets indicated

 

 

are explained later in this sec-

 

 

tion.

Buttons

Function

Changes the Function activated

 

 

by the [Send to] button (*).

 

Send to

Launches the linked applica-

 

Scan

tion software (*).

 

 

 

Power button

Turns the scanner ON and

 

 

OFF.

LED

-

Lights when the scanner is

 

 

turned ON.

*) About the settings on the launcher, refer to FUJITSU TWAIN32 scanner driver help and "fi-5530C2 Oper- ator’s Guide" on the Setup CD-ROM.

Indications on the Function Number Display

The following shows the indications on the Function Number Display.

Indication

Meaning

 

 

8

Lights only one time upon turning on the

scanner.

 

 

P

Indicates that the scanner has been turned

ON and is being initialized.

0

Indicates that initialization will soon be

completed.

 

 

1

Indicates that initialization has been com-

pleted successfully.

 

This status is called "Ready Status."

 

 

U

Indicates that a temporary error (that users

can solve) has occurred during the initial-

 

ization or scanning of documents.

 

[U] and an error number (1, 2, 6) are dis-

 

played alternately.

 

To return the scanner to the ready status

 

([1]), press the [Scan] or [Send to] button

 

while the error is indicated.

E

Indicates that a device alarm (that users can

not solve) has occurred during the initial-

 

ization or scanning of documents.

 

[E] and an alarm number (2 to 9, and, c, d,

 

F) are indicated alternately.

 

To return the scanner to the ready status

 

([1]), press the [Scan] or [Send to] button.

 

If this alarm occurs, turn the power off and

 

then on again. If the alarm is indicated after

 

turning on the power again, contact your

 

servic engineer.

2