Safety instructions
Installation and operation
VCAUTION!
●If the device is integrated in an installation that receives power from an industrial (public) power supply network with the IEC309 connector, the (public) power supply protection must comply with the requirements for the
●The device automatically sets itself to a voltage in the range of
100 V - 240 V. Make sure that your local voltage is within this range.
●This device has a specially approved power cable and must only be connected to a safety socket on the rack mains socket strip.
●The ON/OFF button does not disconnect the device from the mains voltage. To completely disconnect it from the mains voltage, remove the power plug from the safety socket.
●Always connect the device and the attached peripherals to the same power circuit. Otherwise you run the risk of losing data if, for example, the server is still operating but the peripheral device (e.g. storage subsystem) has failed during a power outage.
●Take notice that the data cables to peripheral devices are adequately shielded.
●To the LAN wiring the requirements apply in accordance with the standards EN 50173 and EN
●Route the cables in such a way that they do not form a potential hazard and that they cannot be damaged. When connecting up a device, refer to the relevant notes in this manual.
●Never connect or disconnect data transmission lines during a storm (lightning hazard).
12 | Options Guide | RX600 S4 |