8Controllers in non-hot-plug PCI slots

VCAUTION!

Make sure you observe the safety notes in the chapter “Safety instruc- tions” on page 11ff.

The system board has three non-hot-plug PCIe slots (slots 5 through 7), each with a bandwidth of 2 GB/s and a mounting length of max. 315 mm.

When replacing/installing non-hot-pluggable components, you must proceed as follows:

ÊExit all applications and shut down the server properly.

ÊIf your operating system has not switched off the server, press the On/Off button.

ÊUnplug the power plugs from the grounded power outlets.

8.1Installing controllers

ÊOpen the server as described in the chapter “Preparation” on page 17f.

ÊPlease read the documentation supplied with the PCI board.

ÊPlug any necessary cables into the PCI board.

ÊRemove the slot cover of the relevant slot on the back of the server.

IKeep the slot cover. If you remove a board, you must reinstall the slot cover to comply with EMC (electromagnetic compatibility) regulations and to satisfy cooling requirements and fire protection measures.