Pad ASSY | Plastic roller (x4) |
Eject roller (x2)
Pick roller
Feed roller (x2)
Glass (x2)
(Located on the ADF cover and the base unit.)
For more details, refer to "Chapter 8 Daily Care" in the "ScanSnap S510M Operator’s Guide."
5.4 Cleaning the Carrier Sheet
If the Carrier Sheet is used extensively, dirt and dust may stick onto the surface or the interior and cause scanning errors. Clean it regularly.
<Cleaning method>Use a dry, soft cloth, or a soft cloth slightly moistened with Cleaner F1 or a mild detergent to lightly clean off the dirt and dust from the surface and the interior of the Carrier Sheet.
ATTENTION
•Never use paint thinner or other organic solvents.
•Do not rub too hard. Otherwise, the Carrier Sheet may be scratched or be deformed.
•After cleaning the interior of the Carrier Sheet with Cleaner F1 or a mild detergent, dry the Carrier Sheet completely before closing it.
•As a guideline, it is recommended to replace the Carrier Sheet every 500 scans.
Refer to "6.2 Purchasing the Carrier Sheet" (page 34) for details on purchasing a Carrier Sheet.
ScanSnap S510M Getting Started 32