Fujitsu TX120 Switching the server on and off, Switching the server OFF, Other on/off options

Models: TX120

1 82
Download 82 pages 63.94 Kb
Page 50
Image 50

Switching the server on and off

Starting up and operation

Switching the server OFF

Power-on indicator (item 5 in figure 9 on page 44) lights green.

ÊShut down the operating system properly.

The server is automatically switched off. The power-on indicator lights up orange.

IIf the operating system does not switch the server off automatically, press the On/Off button for at least four seconds and/or send a corre- sponding control signal.

Other on/off options

In addition to the On/Off button, the server can be switched ON and OFF in the following ways:

Specified switch on time / switch off time

The server is switched ON or OFF at a time specified in the ServerView program

Ring indicator

The server is switched on by an internal or external modem.

Wake On LAN (WOL)

The server is switched on by a command via the LAN (Magic Packet).

After power failure

The server automatically reboots following a power failure (depending of the settings in the BIOS).

“Power override” function

The server can be switched off immediately by pressing and holding the On/Off button (approx. 4-5 sec.).

VCAUTION!

There is a risk that data may be lost.

IPMI

The server is switched on by an IPMI console via serial port COM1 (item 4 in figure 6 on page 40) or via the service LAN connection (item 3 in figure 6 on page 40).

50

Operating Manual

TX120

Page 50
Image 50
Fujitsu TX120 manual Switching the server on and off, Switching the server OFF, Other on/off options, Ring indicator