Connections

Connect the signal and power cables, the ground wire and optional equipment as shown in Figure 5-12.

RP

Power cable connector

HDG

Connect power

 

cable here.

 

 

NMEA

10.2-31.2VDC

1 3 GND 2

OPTION

DJ-1

MARINE RADAR

Covered. (not use)

HDG connector Connect heading sensor nere.

NMEA connector Connect navaid nere.

OPTION connector Connect navaid, video sounder, etc.

Signal cable connector Connect signal cable

from antenna here.

TYPE SER.NO.

DATE

COMPASS SAFE DISTANCE

STD M STEER M

EQUPMENT CLASS

FURUNO ELECTRIC CO., LTD

here.

CAUTION

Tighten the boot-band securely to ensure water tightness.

See the procedure in below.

Ground terminal Connect ground wire between

here and ship's ground.

Figure 5-12 Display unit, rear view

Signal cable connection

Rubber cover

1.Connect the signal cable to DJ-1 on the rear panel of the display unit.

Rubber cover

Boot-band

DJ Connector

Cable

DJ-1

Display unit

2.Cover the connector with the rubber cover. The projection on the connector base is in- serted into the groove on the rubber cover.

Grasp

Grasp

Groove

Display unit

3.Put the boot-band as shown below, and tighten it.

Boot-band

Display Unit

33