3.4 Scan Channel Groups
The
You may store a maximum of 10 scan groups, 20 channels per group. Note that scanning is only possible in the ARQ and FEC modes.
Registering Scan Channel Groups
1.Press function key [F5] followed by the [3] key to display the Scan Entry screen.
Scan Entry
Scanning Group List
Create
Change
|
|
|
| Scanning Set Up |
|
| ||
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| Group Name | : |
|
|
|
|
| |
| Ch Dwell Time | : 4.5 sec |
| |||||
| Mode |
| : AUTO ARQ FEC |
| ||||
| Auto Search | : OFF ON |
|
|
| |||
| No | Channel | Rx Freq | Tx Freq | Pass/Scan | |||
1 |
|
|
|
|
|
| Pass/Scan | |
2 |
|
|
|
|
|
| Pass/Scan | |
3 |
|
|
|
|
|
| Pass/Scan | |
4 |
|
|
|
|
|
| Pass/Scan | |
5 |
|
|
|
|
|
| Pass/Scan | |
▼ 6 |
|
|
|
|
|
|
|
Figure 3-8 Scan entry screen
2.If Create is not underlined, press [ ], [ ] and the [Enter] key to underline it.
3.The cursor is on the Group Name line. Enter suitable group name.
4.Press the [ ] key to advance the cursor to the CH Dwell Time line. Enter channel dwell time in seconds. Dwell time is the time in seconds the receiver waits on each channel in a scan group before it selects the next frequency.