SYSTEM MENU 2

MENU SELECT

1

2

3

 

 

 

TIME ADJUST

INTERNAL

EXTERNAL

TIME DIFFERENCE

AUTO

 

MANUAL

 

TIME DIFF HOUR 0

(0

13)

 

 

 

TIME DIFF MIN

0

(0

59)

 

 

 

TIME DIFF SIGN

- , +

 

 

 

0:22:40

▼▲: To select item

-+: To set option Select other mode to exit.

3.4 System Menu 3

RANGE 1- 8: Activates or deactivates specific range scales. Default ranges are 5, 10, 20, 40, 100, 200, 400, and 800 (meters). Setting area is 2 m to 800 m. The ranges 20 m and 200 m can not be changed. They are essential in this equipment.

Note: Ranges must be set in numerical order. For example, if range 1 is 5 m and range 3 is 20 m, range 2 should be between 6 and 19 m.

Trend: The trend index shows the probable bottom shape over a specified time within 1-10 minutes. The default setting is 1 minute.