5 OPERATION OF DIGITAL DEPTH INDICATOR FE-720 (OPTION)

Omnipad

MENU ENT

DISP DIM

*

PWR

2.Press [] or [ ] until the required value is reached. The range of adjustment is from 0 (Min.) to 63 (Max.). The default is 48.

3.Press the ENT key to set.

Note: The contrast is automatically set to the default when you turn on the power.

5.1.4 DEPTH MODE

The Digital Depth Indicator FE-720 is an optional remote display. The panel illumination can be locally adjusted on the control panel or on the optional hand dimmer box.

5.1 Basic Operation

5.1.1 Turning on

Press the POWER key. The unit beeps and starts up with the last-used display. To turn off the unit, press the POWER key again.

5.1.2 Adjusting panel dimmer

1.Press the DIM key.

2.Press [] to increase the dimmer or [ ] to decrease it. The default is level 4.

3.Press the ENT key to finish the adjustment.

5.1.3Adjusting Contrast

1.Press the [] key. The following window appears.

CONTRAST (0-63)

48

EXIT: [ENT]

Depths are read either below transducer (keel) or below seaface irrespective of the main display. Select the mode as below:

1.Press the DISP key to select the wanted mode. The mode changes as below with each press.

DEPTH FORE 50kHz

123 m

BELOW TRANSDUCER

Depth below transducer

DEPTH FORE 50kHz

128 m

BELOW SURFACE*

DRAFT: 5.0 m

Depth below surface. Draft is determined on the main Display Unit FE-701.

*: If the draft setting is –10.0 to -0.1 (refer to page 8.) BELOW KEEL is displayed instead of the BELOW SURFACE.

16

Page 26
Image 26
Furuno FE-700 Operation of Digital Depth Indicator FE-720 Option, Basic Operation, Turning on, Adjusting panel dimmer