3.2 Output Data Sentences

Select output data sentences for external equipment as follows:.

1.Press the [MENU] key.

2.Press the software key labeled "CONFIGURATION".

3.Press the software key labeled "SETUP NMEA PORT 1".

4.Press the software key labeled "SELECT SNTNC." to display the following list.

 

SELECT SENTENCE

SELECT

s

SNTNC.

sAAM

 

 

 

 

 

 

 

APB

ON

ON/OFF

 

BOD

 

 

 

 

 

BWR

 

 

 

GGA

 

 

 

GLL

ON

 

 

MTW

 

 

 

RMA

 

 

 

RMB

ON

 

 

RMC

ON

 

 

VTG

ON

 

 

WPL

 

 

 

XTE

 

 

 

ZDA

ON

 

DGPS 3D

 

 

RETURN

 

 

 

Figure 3-3 Output Data Sentences Display

5.Select data sentence you want to output by the arrow key.

6.Press the software key labeled "ON/OFF". To output data, set to "ON".

7.Repeat to select other sentences.

8.Press the software key labeled "RETURN".

9.Press the [PLOT] key to finish.

Input/Output data sentences

Port

I/O

 

Format

Data

Remarks

 

 

 

 

 

 

 

 

NMEA-0183

 

WPL : GP talker only

 

Input

TLL*1, DWM, WPL*1, DBT/DPT

NMEA Ver 1.5: DBT

 

 

 

Ver. 2.0

 

NMEA Ver 2.0: DPT

1

 

 

Ver. 1.5

 

 

 

 

AAM, APB, BOD, BWC/BWR,

GREAT CIRCLE: BWC

 

 

IEC1162

 

Output

 

 

GGA, GLL, RMA, RMB, RMC, VTG,

RHUMB LINE: BWR

 

 

 

 

WPL, XTE, ZDA, MTW, GTD*2

 

 

 

 

 

 

 

 

 

NMEA-0183

 

WPL: GP talker only

 

Input

TLL*1, DWM, WPL*1, DBT/DPT

NMEA Ver 1.5: DBT

 

 

Ver. 2.0

 

 

 

 

NMEA Ver 2.0: DPT

 

 

 

Ver. 1.5

 

2

 

 

 

 

 

RS232C

AAM, APB, BOD, BWC/BWR,

GREAT CIRCLE: BWC

 

 

 

 

RTCM104

 

Output

GGA, GLL, RMA, RMB, RMC, VTG,

 

 

 

RHUMB LINE: BWR

 

 

 

 

WPL, XTE, ZDA, MTW, GTD*2

 

 

 

 

 

 

 

 

 

 

 

*1: Cannot be input consecutively.

*2: Output automatically when LC or LA is selected.

3-3

Page 15
Image 15
Furuno GP-1850D installation manual Output Data Sentences, Input/Output data sentences