8.Rotate the [ENTER] knob to set digit and push the [ENTER] knob. To clear a line of data, press the [CLR FLD] soft key (one of the keys below the screen).

Setting range

Draft setup: -20 - +39.9 (ft)

Speed calibration: -50 - +50 (%)

Temp calibration: -50 - +5 (°F)

Acoustic speed calibration: -50 - +50 (ms)

9.Set other digits as you did in step 8.

10.Press the [SAVE] soft key (one of the keys below the screen). 11.If necessary, follow steps 5-11 to set other items.

12.Press the [MENU] key to close all open windows and erase the menu bar.

3.4Choosing Data Source(s)

Choose the source of depth, water temperature and speed data as follows:

1.Press the [MENU] key to show the menu bar.

2.Rotate the [ENTER] knob to choose ADVANCED on the menu bar and then push the [ENTER] knob.

3.Rotate the [ENTER] knob to choose INPUT/OUTPUT and then push the [ENTER] knob.

4.Rotate the [ENTER] knob to choose DEPTH SOURCE, TEMP SOURCE or STW SOURCE (speed) depending on your system configuration and then push the [ENTER] knob.

NMEA

Sounder

5.Rotate the [ENTER] knob to choose NMEA or Sounder as appropriate and then push the [ENTER] knob. Choose Sounder if you wish to use sounder-generated depth, water tempera- ture or speed data. (Optional water temperature/speed sensor required to use Sounder-gen- erated water temperature/speed data.)

6.Press W to close the window.

7.If applicable, repeat steps 4 thru 6 to choose other data sources.

8.Press the [MENU] key to close all open windows and erase the menu bar.

Note:The following data sentences are required to display respective data. Depth: DPT (Ver. 2.0)

or DBT (Ver. 1.5), Temperature: MTW, and STW (Speed Thru Water): VTG, RMC or RMA.

32

Page 38
Image 38
Furuno GP-7000F installation manual Choosing Data Sources, Setting range