Optional transducer

The optional Distributor MB-1000 is required to connect the optional transducers 50B-6, 50B-6G, 200B-5S, 200B-5S, 50/200-IT. The optional cable assy 02S4089 (Code No. 000-133-622, 1 m) is required to connect the Distributor.

* R/W = Red/White

Transducer

50kHz

 

 

02P6168

 

 

J2

J1

 

50B-6/6G

 

 

 

 

 

SHIELD

TB2

 

 

 

 

 

1

TB1

 

 

 

 

R/W*

 

 

 

 

 

 

 

 

 

2

BLK

 

 

 

 

R/W*

3

 

 

 

 

 

 

 

 

 

3

2

 

 

 

200kHz

BLK

 

 

 

 

 

 

 

4

 

 

 

 

 

1

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

5

WHT

 

200B-5/5S

 

 

 

 

 

 

 

Shield

Connect 8P connector to cable assy. 02S4089.

Detach grommet; attach cord lock.

Distributor MB-1000, cover removed

Distributor MB-1000 (Code No.: 000-040-809)

Part

Type

Code No.

Qty

Remarks

 

 

 

 

 

Distributor

MB-1000

000-040-805

1

 

 

 

 

 

 

Crimp-on Lug

FV1.25-3, red

000-538-113

6

 

 

 

 

 

 

Cord Lock

NC-1

000-516-650

1

Used to connect two transducers

 

 

 

 

 

Fabricating the transducer cable

Fabricate the transducer cable as below and connect it to the Distributor, referring to the intercon- nection diagram.

Vinyl Sheath

Crimp-on Lug

FV1.25-3, Red

Clamp here.

 

Shield

Taping

Shrink Tubing

How to fabricate the transducer cable

25

Page 31
Image 31