Port, cable and connectable equipment

Port

 

 

Used cable

 

Connectable Equipment

Name

 

Name

Type

Code No.

Standard/

 

Option

 

 

 

 

 

 

 

12-24

 

Power

MJ-A3SPF0017-

000-138-928

Standard

Power source

VDC

 

cable

050Z

 

 

 

 

DVI-D

 

DVI

DVI-D/D

000-149-054

Option

PC, FAR-21X7 series,

 

Cable

SINGLELINK5M

FEA-2107

 

 

 

 

 

 

 

 

 

 

FCV-1200L/1200LM,

RGB1

 

 

3COX-2P-6C

000-146-500

Option

CH-250, CH-270,

 

 

CSH-5L/8L,

 

Analog

5M

 

 

 

 

FSV-24/24S/30/30S,

 

 

 

 

 

 

 

RGB

 

 

 

GD/GP-280/380/680,

 

 

Cable

3COX-2P-6C

 

 

FR-1500 MK3 series,

RGB2

 

 

000-146-501

Option

FR-21X5 series,

 

 

10M

Model 1833C series,

 

 

 

 

 

 

 

 

 

 

 

Model 1833C-BB series

Prepare the following cable locally.

Connector type: RCA (metal), both ends

VIDEO1 ▪ Cable length: shorter than 10 m

2.5C2V or 3C2V (Japan Industrial Standard, or the equivalent) coaxial cable (Impedance: 75 Ω)

 

Cable 3C2V

 

 

Insulator

Video cassette

VIDEO2

 

 

recorder, CCD camera,

 

 

DVD player

 

Shield

 

VIDEO3

Vinyl sheath

Conductor

S = 0.19 mm 2

= 0.5 mm

Grounding

Fasten the ground wire (local supply) between the ground terminal on the display unit and the ship’s superstructure. The length should be as short as possible.

Note: Use a “closed-type” lug ( ) to make the ground connection at the display unit. Do

not use an “open-type” lug ().

6

Page 13
Image 13
Furuno MU-155C manual Grounding, Port, cable and connectable equipment