Furuno SC-110 manual Input/Output Ports, AP-8, Terminal Name, Signal, Label, Remarks

Models: SC-110

1 89
Download 89 pages 1.46 Kb
Page 70
Image 70

APPENDIX

3. Input/Output Ports

Port

Terminal Name

I/O

Signal

Remarks

Label

 

 

 

 

DATA

WAGO

O

Heading,

IEC61162(NMEA0183) or AD-10 format

OUT1

231-304/026-000

 

Speed,

(software)

DATA

WAGO

O

Course,

IEC61162-1 (NMEA0183) Ver1.5, 2.0

OUT2

231-304/026-000

 

Position,

IEC61162-2

DATA

WAGO

O

and

Talker: GP, HE, HN,HC ( HDT, HDM, THS,

OUT3

231-304/026-000

 

Time

ROT selectable; other sent. GP only)

 

 

 

 

Speed: 4800, 9600, 19200, 38400 bps

DATA

WAGO

O

 

 

IEC61162 sentences: HDT, HDM, THS, ROT,

OUT4

231-304/026-000

 

 

 

 

 

 

VTG, GGA, GLL, GNS, ZDA, VHW, VBW,

DATA

WAGO

O

 

 

VDR, RMC ( on/off by menu )

OUT5

231-304/026-000

 

 

 

 

IEC61162 (NMEA0183) : sentence output

 

 

 

 

 

 

 

 

interval : HDT, HDM, ROT : (25ms, 100ms,

 

 

 

 

200ms, 1s, 2s, 20ms, selectable), VTG, GGA,

 

 

 

 

GLL, GNS, ZDA, VHW, VBW, VDR, RMC :

 

 

 

 

(1s, 2s, selectable)

 

 

 

 

ATT sentence

 

 

 

 

Proprietary sentence or FURUNO sentence

 

 

 

 

Only P sentence : output rate of 25ms,

 

 

 

 

100ms,200ms, 1s, 2s, 20ms, selectable

 

 

 

 

ATT sentence – True heading, pitching, rolling

 

 

 

 

$PFEC,GPatt,xxx.x, +xx.x, +xx.x<CR><LF>

 

 

 

 

( IEC61162-1 (NMEA0183) Ver1.5 )

 

 

 

 

$PFEC,GPatt,xxx.x, +xx.x,

 

 

 

 

+xx.x*hh<CR><LF>

 

 

 

 

(IEC61162-1 (NMEA0183) ver 2.0,

 

 

 

 

IEC61162-2)

 

 

 

 

HVE sentence

 

 

 

 

Proprietary sentence or FURUNO sentence

 

 

 

 

Only P sentence : output rate of 25ms,

 

 

 

 

100ms,200ms, 1s, 2s, 20ms, selectable

 

 

 

 

HVE sentence – heave by wave

 

 

 

 

$PFEC,GPhve,xx.xxx,A<CR><LF>

 

 

 

 

( IEC61162-1 (NMEA0183) Ver1.5 )

 

 

 

 

$PFEC,GPhve,xx.xxx,A *hh<CR><LF>

 

 

 

 

(IEC61162-1 (NMEA0183) ver 2.0,

 

 

 

 

IEC61162-2)

 

 

 

 

AD-10 output interval :25ms

 

 

 

 

Signal level : IEC61162

 

 

 

 

Heading data selected in the tech menu is

 

 

 

 

output.