Malfunction With Error Code
Number of Flashing | Possible Cause | Action To Take By Operator Or Operating |
Signals (Code) |
| Personnel |
E03 | Overheated heat sink | Let unit cool down |
| Check air filter and air flow | |
| Verify that air inlet and air outlet are not | |
|
| obstructed with objects |
|
| Clean air filter |
|
|
|
E04 | Overheated cooking zone | Let unit cool down |
| Check air filter and air flow | |
E06 | Overheated electronic | Let unit cool down |
| Check air filter and air flow | |
| Ambient temperature too high (the cooling | Verify that no hot air is sucked in by the fan. |
| system is not able to keep the cooker in normal | Reduce the ambient temperature. The air inlet |
| operating conditions 1) | temperature must be lower than 104°F/40°C |
|
|
|
E07 | Empty cooking sensing element activated | Reset empty cooking protection by switching |
| the unit off | |
E08 | Ambient temperature beyond operating range | Make sure that the operating conditions |
| (especially the ambient temperature) are kept | |
| Error on sensing element | Contact service agent |
|
|
|
Order of error message: The indicator lamp lights up for an interval of 0.6 sec. The number of the following short flashes has to be counted and informs about the kind of error corresponding to the above mentioned code system.
The code will repeat until the error is cancelled.