3.4Powering the Magnum DC 6KM Mobile Ethernet Switches

The DC internal power supply supports installation environments where the DC voltage is from 10 to 300 volts, depending on the 6KM model selected. The power consumption will range from about 10 up to 15 watts, depending on the port quantity and types in the configuration. When connecting the Ethernet cabling, there is no need to power down the unit. Individual cable segments can be connected or disconnected without concern for power-related problems or damage to the unit.

DC power input options are available to suit the 6KM Mobile Ethernet Switches to special high-availability communications and/or heavy industrial-grade applications, including:

*12VDC, -48VDC, 24VDC, 110VDC, 125VDC and 250VDC with single DC input,

*12VDC, -48VDC, 24VDC, 110VDC, 125VDC and 250VDC with dual DC input

*AC input with internal power supply

(see Section 1.2, for Ordering Information)

Fig 3.4a

Single DC power input

Power input connection made with RD 24 4-position (male) locking connector, +, -, NC, NC (Not connected)

(See Appendix B for more information)

Fig 3.4b

Dual-Source DC power input

Power input connection made with RD 24 4-position (male) locking connector, A+,A -, B-, B+

(See Appendix C for more information)

Fig 3.4c

AC power input

Power input connection made with RD 24 4-position (male) locking connector, +, -, GND, NC (Not connected)

(See Appendix D for more information)