Magnum 6KM Mobile Ethernet Switch Installation and User Guide

07/10

AC Power Supply (Internal)

AC Power Connector: RD24 locking, male

100-240VAC Power Input, 47 to 63 Hz (auto-ranging)

Power Consumption:

15 watts Max. (for a fully loaded fiber model with 2Gb) 10 watts Max. (for 8 port copper and 100Mb fiber model)

Dual –Source DC Power Input (Optional)

A Dual-Source option is available for the 12VDC, 24VDC, –48VDC, 110VDC, 125VDC and 250VDC models. This provides for continuity of operation when either of the DC input sources is interrupted. See Appendices B and C.

The Dual-Source power input connector is configured: “ +A, -A, -B, +B ”

Management Console connector

M12 interface, female, see details in Section 3.6

6KM Mounting:

Vertical or horizontal mounting normal. Suitable for wall or DIN-Rail mounting

Agency Approvals and Standards Compliance:

UL listed (UL60950), cUL, CE, Emissions meet FCC Part 15 Class A Shock: IEC 61373, IEC 60068-2-27

Vibration: IEC 61373, IEC 60068-2-6 FC

EN50155 and EN50121-4 Railway Applications Standards NEBS Level 3 and ETSI Compliant

IEEE 1613 Class 2 Environmental Standard for Electric Power Substations See also Note for Power Substations in Section 3.2.1, 3.6.1, and 5.1.2 IEC 61850 EMC and Operating Conditions Class C for Power Substations NEMA TS-2 and TEES for DC-powered and PoE-powered traffic control

equipment

DNV for shipboard and offshore applications

Warranty: Three years

Made in USA

Email info@GarrettCom.com for additional information.