Magnum 6KM Mobile Ethernet Switch Installation and User Guide

07/10

Standard 6KM (Dual Source) male DC Power Input connector:

 

Pin 1=

A+

 

Pin 2=

B+

 

Pin 3=

B-

 

Pin 4=

A-

 

A= Primary circuit

B= Secondary circuit

NOTE: The GND should be hooked up first. The 6KM unit has a floating ground, so the user may elect to Ground either + or - terminal to suit the customer’s use.

Before connecting live power lines to the input connector of –48VDC, 12VDC, 24VDC, 110VDC, 125VDC or 250VDC products, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage lead from 48V or –48V supply must be connected to the post labeled “+”.

After confirmation of the output voltage:

1.Turn off power to the supply line.

2.Connect supply line to the unit.

3.Apply power to the supply line.

4.Confirm that the PWR led is illuminated.

C6.0 ORDERING INFORMATION FOR DUAL SOURCE DC POWER

To order the optional Dual-Source DC power supply factory installed, add “Dual-Src-xxx” as a separate line item following the product model.

Example: Magnum 6KM-48VDC

Dual-Src-48V

www . GarrettCom . com

40

Page 45
Image 45
GarrettCom MAGNUM 6KM manual Standard 6KM Dual Source male DC Power Input connector, Example Magnum 6KM-48VDC Dual-Src-48V