Magnum 6KM Mobile Ethernet Switch Installation and User Guide

07/10

APPENDIX B: DC Single Source Power Input

B1.0 Specifications for Magnum 6KM Switches, DC Power at 12, 24, –48, 110, 125 and 250VDC Power input

Each Magnum Model 6KM Managed Switch requires DC power input, at 12, 24, 48, 110, 125 and 250VDC nominal. The wide range of DC power input types qualifies this product for use in 12, 24, 48, 110, 125 and 250VDC applications in different industries.

DC Power Terminals: “+”, - are internally floating so that user may ground either

GND: ground wire connection to the 6KM chassis (#6-32 thread)

Fig B1.0a Location of chassis ground

Power Consumption:

15 watts typical (for a fully loaded fiber model with 2Gb) 10 watts typical (for 8 ports, copper and 100Mb fiber)

12VDC Power Input nominal (range 10 to 15VDC) 24VDC Power Input nominal (range 18 to 36VDC) -48VDC Power Input nominal (range 36 to 60VDC) 110VDC Power Input nominal (range 77 to 137VDC) 125VDC Power Input nominal (range 88 to 150VDC) 250VDC Power Input nominal (range 160 to 300VDC)

www . GarrettCom . com

35

Page 40
Image 40
GarrettCom MAGNUM 6KM manual Fig B1.0a Location of chassis ground Power Consumption