Magnum 6KM Mobile Ethernet Switch Installation and User Guide | 07/10 |
APPENDIX B: DC Single Source Power Input
B1.0 Specifications for Magnum 6KM Switches, DC Power at 12, 24,
Each Magnum Model 6KM Managed Switch requires DC power input, at 12, 24, 48, 110, 125 and 250VDC nominal. The wide range of DC power input types qualifies this product for use in 12, 24, 48, 110, 125 and 250VDC applications in different industries.
DC Power Terminals: “+”,
GND: ground wire connection to the 6KM chassis
Fig B1.0a Location of chassis ground
Power Consumption:
15 watts typical (for a fully loaded fiber model with 2Gb) 10 watts typical (for 8 ports, copper and 100Mb fiber)
12VDC Power Input nominal (range 10 to 15VDC) 24VDC Power Input nominal (range 18 to 36VDC)
www . GarrettCom . com
35