F - 160 Operation and Maintenance Manual

Applications

 

 

r)Press SPEED s to set a motor speed of 2 ft. / min. ( .6 m / min. )

v)Press STOP.

F W R

2.0 G O

F W R

2.0 G O

S P E E DREV.

S P E E DREV.

S T O P

S A F E T Y

s)Press GAP t to enter a 0 in. gap setting.

G A P P R E S S U R E

0

t)Press GO.

2.0

F W R

G O

S P E E D

REV.

S T O P

S A F E T Y

 

u)Continue with step “v” when the TOP TEMP DISPLAY stops flashing.

S

S A F E T Y

Process

a)Raise the front safety shield and remove the front infeed table.

b)Apply just enough brake tension to prevent the roll of thermal laminate from free spinning.

INFORMATION

Excessive brake tension may cause the output to curl. This can create complications with the second pass of this application.

c)Pull the thermal laminate straight down toward the front infeed table so that approximately 6 in. is resting on the front infeed table. Refer to Figure 6.8.3

© GBC Pro - Tech August 1999

Page 6 - 73