Installation

F - 160 Operation and Maintenance Manual

 

 

4.8.1Control panel

a)Press TOP TEMP. s to a value of 120oF ( 48 oC ). TOP TEMP DISPLAY begins flashing.

SLEEP

TOP TEMP.

BOT. TEMP

120 68

b)Press BOT TEMP s to a value of 120oF ( 48 oC ). BOT TEMP DISPLAY begins flashing.

SLEEP

TOP TEMP.

BOT. TEMP

120 120

d)Press GAP s. GAP DISPLAY increases 1/16th of an inch per press. The upper main roll moves accordingly. Once to “1”, the upper main roller stops.

GAP PRESSURE

0 - 1

e)Press and hold PRESSURE t. The upper main roller travels in a constant downward motion. Once making contact with the lower main roller, the bars turn solid one at a time until all 10 bars are solid.

GAP PRESSURE

0

c)Press GAP t once. GAP DISPLAY decreases 1/16th of an inch per press. The upper main roller moves accordingly. Once to “0”, the upper main roller is contacting the lower main roller.

f)Press and hold PRESSURE s. The upper main roller travels in a constant upward motion. The pressure bars turn hollow one at a time until no bars are solid and GAP DISPLAY changes to “1” then stops.

GAP PRESSURE

1 - 0

GAP

PRESSURE

 

1

Page 4 - 18

© GBC Pro - Tech August 1999