Operations

F - 160 Operation and Maintenance Manual

 

 

( 5 ) BOT. TEMP. DISPLAY : The display will show the set point temperature of the bottom main roller as the default display. When the bottom roller temperature has reached in the +/- 10oF range of the set point, the display will be solid. When outside of this range, the display will flash.

SLEEP

TOP TEMP.

 

BOT. TEMP

 

 

 

 

 

 

 

32 32

5

( 6 ) BOT. TEMP. s: When pressed, will increase the set point value of the bottom main roller in increments of 2 degrees. If this key is held down, it will only increase to the maximum temperature setting of 290oF ( 143oC ).

6

SLEEP

TOP TEMP. BOT. TEMP

68 68

( 8 ) GAP DISPLAY : Displays the current main roller nip opening. The nip has a range of 0 to 1” gap.

GAP PRESSURE

1/4

8

( 9 ) GAP s: When pressed, will increase the gap by 1/16 in. increments. If held down, it will automatically increase the gap by 1/16 in. increments until it has reached a maximum opening of 1 in. on the GAP DISPLAY.

9

GAP PRESSURE

1/4

( 7 ) BOT. TEMP. t : When pressed, will decrease the set point value of the bottom main roller in increments of 2 degrees. If held down, it will decrease to the minimum temperature setting of 68oF ( 20oC ).

( 10 ) GAP t : When pressed, will decrease the gap by 1/16 in. increments. If held down, it will automatically decrease the gap by 1/16 in. increments until it has reached a minimum opening of 0 in. on the

GAP DISPLAY.

 

 

GAP

PRESSURE

SLEEP

 

1/4

 

TOP TEMP.

BOT. TEMP

 

 

 

68

68

10

 

 

 

7

 

Page 5 - 2

© GBC Pro - Tech August 1999