F - 160 Operation and Maintenance Manual

Maintenance

 

 

d)Since the safety shields are raised and the tables removed, you must use the footswitch to rotate the bottom rollers after cleaning a section.

CAUTION

Speed is controlled through the variable speed footswitch when the safety shield is in the raised position.

Method 2

a)Allow the laminator to cool slightly to no higher than 110oF ( 43oC ).

SLEEP

TOP TEMP.

BOT. TEMP

<110 <110

b)Set the motion direction to REV t.

WARNING

Keep hands and fingers clear of the laminator roller nip when changing GAP. Yo u ca n b e CRUSHE D o r BURNED!

b)Set the nip of the rollers to the thickness of the adhesive coated boards.

G A P P R E S S U R E

1/4

WARNING

Keep hands and fingers clear of the laminator roller nip when adjustin g PRESSURE .

Yo u ca n b e CRUSHE D o r BURNED!

c)Using the variable speed footswitch, run

the adhesive coated boards through the rolls.

00.0 G O

F W R

S P E E DREV.

S T O P

S A F E T Y

d)Do this as many times as needed to clean the laminator rolls.

© GBC Pro - Tech August 1999