F - 160 Operation and Maintenance Manual

Operations

 

 

Section 5 Operations

The operator control panel for the Falcon 160 Laminator is located on the front of the machine, to the right of the front operating position.

( 2 ) TOP TEMP DISPLAY : The display will show the set point temperature of the top main roller as the default display. When the top roller temperature has reached in the +/- 10oF range of the set point, the display will be solid. When outside of this range, the display will flash.

For an illustration of the complete front control

 

panel, please refer to Figure 5.1.1. The names and

 

functions of these controls are as follows:

2

 

SLEEP

TOP TEMP.

BOT. TEMP

32 32

INFORMATION

When any command is pressed on the control panel, a "beep" will sound. If the command is held down, the panel will "beep" only once.

5.1 Control Panel

( 3 ) TOP TEMP s : When pressed, will increase the set point value of the top main roller in increments of 2 degrees. If held down, it will only increase to the maximum temperature setting of 290oF ( 143oC ).

3

SLEEP

TOP TEMP.

 

BOT. TEMP

 

 

 

 

 

 

 

32 32

( 1 ) SLEEP: If flashing, the machine is in sleep mode. This will occur after 3 hours of no activity. To wake the laminator from sleep mode, press any command.

1

( 4 ) TOP TEMP t : When pressed, will decrease the set point value of the top main roller in increments of 2 degrees. If held down, it will only decrease to the minimum temperature setting of 68oF ( 20oC ).

SLEEP

 

SLEEP

 

TOP TEMP.

BOT. TEMP

 

TOP TEMP.

BOT. TEMP

 

 

32

32

32

32

 

 

 

4

© GBC Pro - Tech August 1999