2.Aluminum lViring
A. Connect length of copper building wire to range terminal block.
IL Splice copper wires to aluminum wiring using special connectors designed and UT.L. approved for joining copper to aluminum, and follow the connector manufac~urer’s recommended procedure closely.
NOTE: WTire used, location and enclosure of splices, etc., must conform to good wiring practice and local codes.
STEP 5
4-WIRE SYSTEM
SPECIAL GROUNDING INSTRUCTIONS
WARNING:
I;rame grounded to neutral of appliance through a link. If usecl in a MOBILE HOME or if LOCAL CODE3S do not permit grounding through the neutral:
1)disconnect the link from neutral,
2)use grounding terminal or lead to ground unit in accordance with local codes, and
3)connect nrutra] terminal 01- lead to branch circuit in usual manner.
(If the appliance is to be connected bv means of a cord set, use
CO NNECT”O
BL.OCK
4TH G | \ GRO LJND | |
LUG | ||
|
|
|
|
|
|
STEP b
ANTI-TIP BRACKET INSTALLATION
AN
WARNING
1.Range must be secured by
2.See instructions to install (supplied with bracket).
3.Unless properly installed, range could be tipped by stepping or sitting on door. Injury might result from spilled hot liquids or from range itself.
Typical installation of
Attachment to Wall
Bracket
STEP 7
LEVELING THE RANGE
The range must be level. Leveling feet are located at each corner of the base of the range. Remove the storage drawer or kick panel (depending on your model) and using channel locks, rotate the leveling feet in and out as required to level the range. (For instructions on how to remove and replace the storage drawer or the kick panel, see the Cleaning [Jnder the Range section in Care and Cleaning.) On some models, there are plastic covers which may be removed for easy adjustment (just squeeze and pull).
One of the rear leveling feet will engage the
Check the range for proper installation into the
STEP 8
FINAL CHECK
Be sure all switches are in the OFF position before leaving the range.